CPHA = 1 (clock is valid on trailing edge) for proper display of translated byte data
Continuous Write Example is for writing registers from 0x00 to 0x0B at once, starting with Register 0x00
(in GUI test tab with EVM, Send 110021020000C1BB00301F214087, like Set Protocol Example 2, but all at one time)
Continuous Read Example is read back of the Continuous Write Example, from register 0x00 to 0x0B
(in GUI test tab with EVM, Send 130C)

Set Protocol 1 = low data rate, single subcarrier, 1 of 4 data coding, full power(200mW)
Set Protocol 2 = high data rate, single subcarrier, 1 of 4 data coding, full power(200mW)
Set Protocol 3 = low data rate, double subcarrier, 1 of 4 data coding, full power(200mW)
Set Protocol 4 = high data rate, double subcarrier, 1 of 4 data coding, full power(200mW)
Set Protocol 5 = low data rate, single subcarrier, 1 of 4 data coding, half power(100mW)
Set Protocol 6 = high data rate, single subcarrier, 1 of 4 data coding, half power(100mW)
Set Protocol 7 = low data rate, double subcarrier, 1 of 4 data coding, half power(100mW)
Set Protocol 8 = high data rate, double subcarrier, 1 of 4 data coding, half power(100mW)

Single Write Example is for showing one register write at a time
(in GUI test tab with EVM, Send 100021, as example for writing register 0x00 with 0x21)
Single Read Example is for showing one register read at a time
(in GUI test tab with EVM, Send 1200, as example for reading register 0x00 back from the single write)